Learn More
Beschreibung
The Thermo Scientific Pierce HeLa Digest/PRTC Standard is a validated complex mammalian protein digest containing additional PRTC heavy isotope-labeled peptides designed for LC/MS performance testing.
Features of HeLa Digest/PRTC Standard include:
- Convenient—pre-mixed formulation of HeLa digest and PRTC standard in a ready-to-use format
- Informative—enables robust performance assessment of LC/MS instruments
- Verified—high-quality, consistent mixture documented via lot-specific certificates of analysis
- Stable—provided in a lyophilized format
The Pierce HeLa Digest/PRTC Standard is a lyophilized mixture of 10 μg of HeLa protein digest with 5 pmol PRTC peptides to assess chromatography MS instrument performance. The protein digest is derived from a well-established adenocarcinoma reference HeLa S3 cell line that expresses over 15,000 proteins with relevant post-translational modifications. This complex digest is an ideal standard for complex proteome mass spectrometry applications.
The included Pierce Peptide Retention Time Calibration Mixture contains 15 synthetic heavy isotope-labeled peptides mixed at an equimolar ratio that elute across the chromatographic gradient. The observed retention times and hydrophobicity factors (HFs) for these calibrant peptides are fit to a linear equation to determine the slope of the retention time/HF relationship. This equation and the HF of an uncharacterized peptide are then used to predict retention time. In combination, the mixture is a powerful tool to optimize and assess LC parameters, identify the total peptide elution window, and optimize and monitor MS instrumentation.
This standard is specifically formulated for LC/MS experiments and does not contain salts or detergents. Using the standard routinely before analysis of complex samples makes it possible to monitor and normalize LC/MS performance between samples and over time.
Applications:
- Qualitative LC assessment
- QC assay tool for assessment of LC/MS system performance
- LC/MS standardization
- LC/MS method development and optimization
- Normalize results for variation in retention times and peak intensities between runs
Spezifikation
Spezifikation
| Chemischer Name oder Material | HeLa Digest/PRTC Standard |
| Verpackung | Lyophilized in glass vial |
| Synonym | HeLa/PRTC |
| Menge | 5 x 10 μg |
| Güte | MS |
Indem Sie auf Absenden klicken, erklären Sie sich damit einverstanden, dass Fisher Scientific sich mit Ihnen in Verbindung setzen kann, um Ihr Feedback in diesem Formular zu bearbeiten. Wir werden Ihre Informationen nicht für andere Zwecke weitergeben. Alle bereitgestellten Kontaktinformationen werden in Übereinstimmung mit unserer Datenschutzrichtlinie aufbewahrt. Datenschutzrichtlinie.